Showing 1–12 of 51 results

نمایش 9 24 36

AVT

The AVT is an electronic air velocity and temperature transmitter for air and non-combustible gases with optional relay output.

AVT series air velocity transmitters are engineered for building automation in the HVAC/R industry. The AVT measures air velocity and temperature, with field selectable range and output options in a single device. Designed with a duct mount probe and adjustable collar suitable for round or rectangular ducts.

AVT series devices include: • 3 field selectable measurement ranges for air velocity, selectable via jumper. • Separate readings and outputs for air velocity and temperature. • Proportional output options include: voltage (0–10 V) and current (4–20 mA).

AVT series device options offer: • Display • Field adjustable relay

CDT-MOD-2000

Multifunctional CO2 transmitters for building automation systems that use Modbus serial communication protocol

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy. Configuration is also possible via Modbus network.

The CDT-MOD-2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 series devices include:

• Separate field configurable Modbus output for each measurement parameter (CO2, rH, T)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• One analog output for selected measurement: voltage (0/2–10 V) or current (4–20 mA)

•  2″ x 3″ touchscreen display

• Time extension button that enables boosting ventilation manually using the touchscreen display

• Optional relay output

CDT-MOD-2000

Multifunctional CO2 transmitters for building automation systems that use Modbus serial communication protocol

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy. Configuration is also possible via Modbus network.

The CDT-MOD-2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 series devices include:

• Separate field configurable Modbus output for each measurement parameter (CO2, rH, T)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• One analog output for selected measurement: voltage (0/2–10 V) or current (4–20 mA)

•  2″ x 3″ touchscreen display

• Time extension button that enables boosting ventilation manually using the touchscreen display

• Optional relay output

CDT-MOD-2000 DUCT

CO2 transmitters with temperature output for duct that use Modbus serial communication protocol

CDT-MOD-2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT-MOD-2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT-MOD-2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 Duct series devices include:

• Separate Modbus output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2 and T)

• Mounting flange

• Clear backlit display

CDT-MOD-2000 DUCT

CO2 transmitters with temperature output for duct that use Modbus serial communication protocol

CDT-MOD-2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT-MOD-2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT-MOD-2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 Duct series devices include:

• Separate Modbus output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2 and T)

• Mounting flange

• Clear backlit display

CDT2000

Multifunctional CO2 transmitters for building automation systems

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy.

The CDT2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC is also suitable for buildings that are continuously occupied.

CDT series devices include:

• Separate field configurable output for each measurement parameter (CO2, rH, T)

• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• Time extension button that enables boosting ventilation manually using the touchscreen display (models with relay)

CDT2000 series device options offer:

• 2” x 3” touchscreen display

• Field configurable relay for any of the three parameters

• Modbus configuration

CDT2000 DUCT

CO2 transmitters with temperature output for duct

CDT2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT2000 Duct series devices include:

• Separate output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2, T)

• Mounting flange

CDT2000 Duct series device options offer:

• Clear backlit display

• Modbus RTU interface

• 4-20 mA proportional output

DPG

The DPG is a standard pressure gauge for measuring overpressure and differential pressure.

The DPG series differential pressure gauges are engineered for HVAC/R applications. The DPG series devices detect air and non-corrosive gas pressures (differential and positive) and provide a clear analog display of the measured values. The DPG series devices include field adjustable zero point calibration and overpressure protection.

DPG/PS

Combination of a differential pressure gauge and a differential pressure switch

In many situations filter monitoring requires an alarm signal and a local display. Our filter alerts are the right solution for these situations. The DPG/PS filter alerts combine differential pressure switches with gauges into one practical product offering.

DPI

Electronic differential pressure switch and transmitter

The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.

The DPI includes the following field selectable features: • Configurable switching point: Open on rise or fall in pressure • Hysteresis of setpoint • Measurement units (Pa, kPa, mmWC, inWC, mbar) • Measurement range (4 ranges per model) • Output signal (0−10 V, NO/NC) • Span and zero point calibration

DPT-2W

Multi-range differential pressure transmitters with 2-wire configuration

DPT-2W series differential pressure transmitters are engineered for building automation in the HVAC/R industry. The DPT-2W measure static and differential pressure and they have a field selectable range.

DPT-2W series devices include: • 8 field selectable measurement ranges, unidirectional or bi-directional, selectable via jumper • Pressure measurement in Pa • 4-20 mA 2-wire current loop configuration

DPT-CTRL

DPT-Ctrl is a multifunctional PID controller with differential pressure or air flow transmitter.

DPT-Ctrl enables to control constant pressure or flow of fans, VAV systems or dampers. Its two lined display shows the direction of the control output and the measurement value at the same time. It is possible to select either current or voltage for both the control output and the differential pressure or flow output. The optional autozero function eliminates the need for periodic manual zero point calibration.

company products hkinstruments