DPT-IO-MOD

Differential pressure transmitter with Modbus communication and Input terminal

The DPT-IO-MOD differential pressure transmitter for air conforms to Modbus over serial line protocol using RTU transmission mode and RS485 interface. The digital output signal is sent over Modbus enabling the DPT-IO-MOD to connect directly to a field communications network.

DPT-IO-MOD requires less wiring than the traditional 3-wire transmitters since multiple devices can be connected on serial line.

The DPT-IO-MOD includes an Input terminal that enables reading of multiple other signals such as temperature or control relays over Modbus. The Input terminal has two input channels designed to accept 0−10 V, NTC10k, Pt1000, Ni1000/(-LG), and BIN IN (potential free contact) signals. For example, DPT-IO-MOD can read values from one differential pressure measurement point and two temperature measurement points. Hence, the DPT-IO-MOD does the work of three transmitters.

DPT-MOD

Multifunctional differential pressure transmitters with air flow measurement and Modbus communication

DPT-MOD is a multifunctional transmitter for measuring volume flow, velocity, and static and differential pressure. The measurements can be read and the configuration done via Modbus communication. DPT-MOD requires less wiring than the traditional 3-wire transmitters because multiple devices can be connected on serial line. DPT-MOD can also be used with several different measurement probes such as FloXact™ or pitot tube, and air dampers.

DPT-MOD series devices include: • Two selectable functions: o Measure and monitor in-duct volume flow, velocity or differential pressure o Measure and monitor air flow across centrifugal fans • Multiple selectable measurement units: o Volume flow: m3/s, m3/h, cfm, l/s o Velocity: m/s, ft/min o Pressure: Pa, inWC, mmWC, kPa, mbar • Modbus communication protocol

DPT-MOD series device options offer: • AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy

DPT-MOD

Multifunctional differential pressure transmitters with air flow measurement and Modbus communication

DPT-MOD is a multifunctional transmitter for measuring volume flow, velocity, and static and differential pressure. The measurements can be read and the configuration done via Modbus communication. DPT-MOD requires less wiring than the traditional 3-wire transmitters because multiple devices can be connected on serial line. DPT-MOD can also be used with several different measurement probes such as FloXact™ or pitot tube, and air dampers.

DPT-MOD series devices include: • Two selectable functions: o Measure and monitor in-duct volume flow, velocity or differential pressure o Measure and monitor air flow across centrifugal fans • Multiple selectable measurement units: o Volume flow: m3/s, m3/h, cfm, l/s o Velocity: m/s, ft/min o Pressure: Pa, inWC, mmWC, kPa, mbar • Modbus communication protocol

DPT-MOD series device options offer: • AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy

DPT-PRIIMA

High accuracy transmitter for demanding applications

DPT-Priima is a high accuracy differential pressure transmitter designed for cleanrooms and other demanding applications. DPT-Priima has a new, extremely accurate sensor and automatic zero point calibration, and optional span point calibration.

DPT-Priima together with SPP (static pressure port) is a complete solution for building envelope measurement.

HK_Instruments_SPP_static_pressure_port-300x182

DPT-R8

DPT-R8 series differential pressure transmitters are engineered for building automation in the HVAC/R industry. The most technologically advanced transmitters on the market measuring static and differential pressure, with field selectable units, range and output, all in a single device.

DPT-R8 series devices include: • Multiple measurement units, field selectable via jumper, including: inWC, mmWC, Pa, mbar. • 8 field selectable measurement ranges, unidirectional or bi-directional, selectable via jumper. • Proportional output options including: voltage (0–10 V / 2-10 V) and current (4–20 mA).

DPT-R8 series device options offer: • AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy • Backlit display • Field adjustable span point calibration (i.e. gain)

DPTL

Differential pressure transmitter for liquid

The DPTL is made for differential pressure detection in liquids for air-conditioning, heating and water systems. The equipment can withstand mildly corrosive substances and liquids.

Applications

PTL and DPTL series pressure transmitters are suitable for measuring pressure in neutral fluids and non-aggressive gases. Also compatible with refrigerants. They are suitable for all kind of tasks in air-conditioning, heating and water systems.

EP-FS- Firemans Switches

کلید آتش نشانی

This range of Safety Switches in lower case is for use in the event of fire or other emergency. Usually located at exits to gas plant rooms, units are key operated with a 2 or 3-position latching switch. It is ideal for use in situations where a glass window would pose a hazard, i.e. food preparation areas, schools etc.

EP-KL – Emergency Stop Button Key Lock Mushroom Type

کلید قارچی استپ اضطراری قفل دار

Emergency Stop Button, lock re-set with 2 sets of keys provided.

EP-SW-11 – Emergency Stop Button

کلید استپ اضطراري

Emergency stop button, twist to re-set for manual shutdown of systems in the event of fire or other emergency.

FC-ITR Manual Speed Controllers

کنترلر سرعت موتور

This range of manual speed controllers provide single-phase voltage control for AC motors, by varying the supplied voltage through phase-angle control.

FC-MTY Electronic Speed

کنترلر ولوم دار سرعت موتور

Manual control for small, single-phase motors up to 4 amps. Suitable for wall and/or flush mounting.

FlOXACT

FloXact measurement probes

The FloXact™ probe is a differential air pressure device designed to measure air volume flow in a duct. It includes multiple sensing points to measure total and static pressures. The FloXact™ probe incorporates a unique design to amplify the differential pressure by 2.5 times for accurate measurement of lower air velocities down to 1.0 m/s (200 fpm). It is easy to install and cost-effective.

• Multiple sensing points for greater accuracy • Easy installation • Chamfered sensing points for consistent readings • 2 % accuracy • 2.5 X signal amplification • Accepts 1/4″ OD tubing