نمایش دادن همه 2 نتیجه

نمایش 9 24 36

CDT2000

Multifunctional CO2 transmitters for building automation systems

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy.

The CDT2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC is also suitable for buildings that are continuously occupied.

CDT series devices include:

• Separate field configurable output for each measurement parameter (CO2, rH, T)

• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• Time extension button that enables boosting ventilation manually using the touchscreen display (models with relay)

CDT2000 series device options offer:

• 2” x 3” touchscreen display

• Field configurable relay for any of the three parameters

• Modbus configuration

CDT2000 DUCT

CO2 transmitters with temperature output for duct

CDT2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT2000 Duct series devices include:

• Separate output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2, T)

• Mounting flange

CDT2000 Duct series device options offer:

• Clear backlit display

• Modbus RTU interface

• 4-20 mA proportional output