CDT-MOD-2000

Multifunctional CO2 transmitters for building automation systems that use Modbus serial communication protocol

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy. Configuration is also possible via Modbus network.

The CDT-MOD-2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 series devices include:

• Separate field configurable Modbus output for each measurement parameter (CO2, rH, T)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• One analog output for selected measurement: voltage (0/2–10 V) or current (4–20 mA)

•  2″ x 3″ touchscreen display

• Time extension button that enables boosting ventilation manually using the touchscreen display

• Optional relay output

CDT-MOD-2000 DUCT

CO2 transmitters with temperature output for duct that use Modbus serial communication protocol

CDT-MOD-2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT-MOD-2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT-MOD-2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT-MOD-2000 Duct series devices include:

• Separate Modbus output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2 and T)

• Mounting flange

• Clear backlit display

CDT2000

Multifunctional CO2 transmitters for building automation systems

CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy.

The CDT2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC is also suitable for buildings that are continuously occupied.

CDT series devices include:

• Separate field configurable output for each measurement parameter (CO2, rH, T)

• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)

• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)

• Time extension button that enables boosting ventilation manually using the touchscreen display (models with relay)

CDT2000 series device options offer:

• 2” x 3” touchscreen display

• Field configurable relay for any of the three parameters

• Modbus configuration

CDT2000 DUCT

CO2 transmitters with temperature output for duct

CDT2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.

The CDT2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC Duct is also suitable for buildings that are continuously occupied.

CDT2000 Duct series devices include:

• Separate output for each measurement parameter (CO2 and T)

• Offset feature enabling field calibration for each measurement parameter (CO2, T)

• Mounting flange

CDT2000 Duct series device options offer:

• Clear backlit display

• Modbus RTU interface

• 4-20 mA proportional output

SIRO

Multifunctional indoor air quality transmitters for building automation systems

Siro is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. It offers easy installation and adjustment, several different model options and various output signals that are configurable separately for each measurement parameter.

The Siro series devices are available with a user interface that includes an LCD display and buttons making the configuration of the device quick and easy. An external configuration tool is available for devices without the user interface. Siro utilizes the industry standard NDIR measurement principle with self-calibrating ABC logicTM for CO2 measurement.

Siro series devices include:

  • Several options for indoor air quality measurements (CO2, VOC, PM, rH, T).
  • Field configurable outputs for selected measurements.
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA).
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, rH, T).
  • Optional LCD-display and buttons.

SIRO-MOD

Multifunctional indoor air quality transmitters for building automation systems that use Modbus serial communication protocol

Siro-MOD is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. It offers easy installation and adjustment, several different model options and various output signals that are configurable separately for each measurement parameter.

The Siro-MOD series devices are available with a user interface that includes an LCD display and buttons making the configuration of the device quick and easy. An external configuration tool is necessary for commissioning preparations for Siro-MOD without the user interface. Configuration is also possible via Modbus network. Siro-MOD utilizes the industry standard NDIR measurement principle with self-calibrating ABC logicTM for CO2 measurement.

Siro-MOD series devices include:

  • Several options for indoor air quality measurements (CO2, VOC, PM, rH, T).
  • Field configurable outputs for selected measurements.
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA).
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, rH, T).
  • Optional LCD-display and buttons.