CDT2000
Multifunctional CO2 transmitters for building automation systems
CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy.
The CDT2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT2000-DC is also suitable for buildings that are continuously occupied.
CDT series devices include:
• Separate field configurable output for each measurement parameter (CO2, rH, T)
• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)
• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)
• Time extension button that enables boosting ventilation manually using the touchscreen display (models with relay)
CDT2000 series device options offer:
• 2” x 3” touchscreen display
• Field configurable relay for any of the three parameters
• Modbus configuration
محصولات مرتبط
DPT-DUAL-MOD
Field adjustable differential pressure transmitter with two pressure sensors for air and an Input terminal for two analog inputs for external signal conversion into Modbus.
DPT-Dual-MOD combines two differential pressure transmitters into one device. It offers a possibility to measure pressure from two different points. It has a Modbus interface and an Input terminal. When using the Input terminal, temperature transmitters can be replaced with temperature sensors. As a result you will save in costs of the devices and in the installation costs. The AHU model that includes an air flow transmitter has been designed especially for ventilation units.
DPT-Dual-MOD series devices include: • Multiple measurement units, field selectable via menu, including: Pa, mbar, inchWC, mmWC and psi. • Input terminal enabling reading of multiple other signals such as temperature or control relays over Modbus
CDT-MOD-2000
Multifunctional CO2 transmitters for building automation systems that use Modbus serial communication protocol
CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy. Configuration is also possible via Modbus network.
The CDT-MOD-2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC is also suitable for buildings that are continuously occupied.
CDT-MOD-2000 series devices include:
• Separate field configurable Modbus output for each measurement parameter (CO2, rH, T)
• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)
• One analog output for selected measurement: voltage (0/2–10 V) or current (4–20 mA)
• 2″ x 3″ touchscreen display
• Time extension button that enables boosting ventilation manually using the touchscreen display
• Optional relay output
DPT-R8
DPT-R8 series differential pressure transmitters are engineered for building automation in the HVAC/R industry. The most technologically advanced transmitters on the market measuring static and differential pressure, with field selectable units, range and output, all in a single device.
DPT-R8 series devices include: • Multiple measurement units, field selectable via jumper, including: inWC, mmWC, Pa, mbar. • 8 field selectable measurement ranges, unidirectional or bi-directional, selectable via jumper. • Proportional output options including: voltage (0–10 V / 2-10 V) and current (4–20 mA).
DPT-R8 series device options offer: • AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy • Backlit display • Field adjustable span point calibration (i.e. gain)
CDT-MOD-2000
Multifunctional CO2 transmitters for building automation systems that use Modbus serial communication protocol
CDT series air quality transmitters are engineered for building automation systems in the HVAC/R industry. The CDT series measures carbon dioxide (CO2) utilizing the industry standard NDIR measurement principle, and temperature (T). Optional relative humidity (rH) measurement is also available in the same device. CDT series devices are available with large touchscreen display making configuration of the device quick and easy. Configuration is also possible via Modbus network.
The CDT-MOD-2000 series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC is also suitable for buildings that are continuously occupied.
CDT-MOD-2000 series devices include:
• Separate field configurable Modbus output for each measurement parameter (CO2, rH, T)
• Offset feature enabling field calibration for each measurement parameter (CO2, rH, T)
• One analog output for selected measurement: voltage (0/2–10 V) or current (4–20 mA)
• 2″ x 3″ touchscreen display
• Time extension button that enables boosting ventilation manually using the touchscreen display
• Optional relay output
CDT-MOD-2000 DUCT
CO2 transmitters with temperature output for duct that use Modbus serial communication protocol
CDT-MOD-2000 Duct combines CO2 and temperature measurements in one device installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The CDT-MOD-2000 Duct has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.
The CDT-MOD-2000 Duct series transmitters calibrate themselves automatically using ABC logicTM. The ABC logicTM requires that the space in which the transmitter is used needs to to be unoccupied for four hours per day so that the indoor CO2 concentration drops to the outside level. CDT-MOD-2000-DC Duct is a dual channel model with a measuring channel and a reference channel that makes a continuous comparison and the necessary adjustment accordingly. CDT-MOD-2000-DC Duct is also suitable for buildings that are continuously occupied.
CDT-MOD-2000 Duct series devices include:
• Separate Modbus output for each measurement parameter (CO2 and T)
• Offset feature enabling field calibration for each measurement parameter (CO2 and T)
• Mounting flange
• Clear backlit display
DPT-Dual
Field adjustable, multi-range differential pressure transmitters with two pressure sensors for air
DPT-Dual series differential pressure transmitters are engineered for building automation in the HVAC/R industry. DPT-Dual is a technologically advanced transmitter measuring static and differential pressure from two different points, with field selectable units, range and output, all in a single device.
DPT-Dual series devices include:
• Multiple measurement units, field selectable via jumper, including: inWC, mmWC, Pa, mbar. • 8 field selectable measurement ranges, unidirectional or bi-directional, selectable via jumper.
RHT
Humidity transmitters for building automation systems
RHT relative humidity transmitters are engineered for building automation systems in the HVAC/R industry. The RHT measures relative humidity (rH), and temperature (T). RHT devices are available with large touchscreen display making configuration of the device quick and easy.
RHT devices include:
• Separate field configurable output for each measurement parameter (rH and T)
• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)
• Offset feature enabling field calibration for each measurement parameter (rH, T)
RHT series device options offer:
• 2” x 3” touchscreen display
• Field configurable relay for any of the two parameters
• Modbus configuration
DPT-CTRL-MOD
Multifunctional two-setpoint PID controller with differential pressure or air flow transmitter and Modbus communication.
DPT-Ctrl-MOD enables to control constant pressure or flow of fans, VAV systems or dampers. In addition, the controller is fully programmable via Modbus.
The DPT-Ctrl-MOD includes an Input terminal that enables the reading of multiple signals such as temperature or control relays over Modbus. The Input terminal has one input channel designed to accept 0−10 V, NTC10k, Pt1000, Ni1000/(-LG), and BIN IN (potential free contact) signals.
The device has a binary input to select between two user-adjustable setpoints. The desired setpoint can be selected, for example, with weekly clock, turn switch or key card switch.
Issac Um –
I appreciate, cause I discovered just what I was having a look for. You’ve ended my 4 day lengthy hunt! God Bless you man. Have a great day. Bye
http://www.vorbelutrioperbir.com
zoritoler imol –
I got what you mean , appreciate it for posting.Woh I am thankful to find this website through google. “Food is the most primitive form of comfort.” by Sheila Graham.
https://www.zoritolerimol.com
Hawkplay –
Join a global community for battles. Hawkplay
tlover tonet –
Greetings! Very helpful advice on this article! It is the little changes that make the biggest changes. Thanks a lot for sharing!
http://www.tlovertonet.com/
hire a hacker online –
Hello There. I found your blog using msn. This is a very well written article. I’ll make sure to bookmark it and come back to read more of your useful info. Thanks for the post. I’ll definitely return.
https://www.javelincloud.com/hire-a-hacker-for-iphone/
professional hackers for hire –
Hello my loved one! I want to say that this post is amazing, great written and include almost all important infos. I?¦d like to see more posts like this .
https://www.circle13.com/
Kera Biotics –
Merely wanna comment on few general things, The website pattern is perfect, the subject material is very excellent. “The way you treat yourself sets the standard for others.” by Sonya Friedman.
https://youtu.be/CDPkB9NIJGg
Boostaro reviews –
I would like to thnkx for the efforts you have put in writing this site. I am hoping the same high-grade web site post from you in the upcoming as well. Actually your creative writing abilities has encouraged me to get my own blog now. Really the blogging is spreading its wings fast. Your write up is a good example of it.